+6

RMS Express P2P Packet not able to receive message

Kevin Noall 13 jaar geleden bijgewerkt door KM6KAQ 7 jaar geleden 6
I'm getting an error message when RMS Express is tring to receive a Peer to Peer Packet message...
*** Link Error - Received data stream not correct format...
I'm able to send messages just fine. 
I'm using an AEA PK-232mbx

I am also seeing this, using telnet winlink. I'm a little scared of this. Telnet winlink should be the easiest to get right and it's not working reliably. I see this error quite frequently.

*** Requesting connection to Perth
*** Connected to Perth
[WL2K-2.7.0.6-B2FWIHJM$]
;PQ: 76254273
Perth CMS >
[RMS Express-1.1.3.0-B2FHM$]
;PR: 34507059
; WL2K DE W1SOP (FN31FG)
FC EM 9VCPUUFMMY07 147 142 0
FC EM GM55XAE5IPV2 150 144 0
F> 10
FS YY
*** Sending 9VCPUUFMMY07...
*** Sending GM55XAE5IPV2...
*** Unable to save received message to database - possible data or size error - Disconnecting (24.2.200.138)
*** Disconnected


here's the message it's trying to send. Nothing complicated"

Message ID: GM55XAE5IPV2
Date: 2011/10/20 05:17
From:
To: sander_pool@pobox.com
Source: W1SOP-0
Subject: //WL2K to -0

asdasdasd

Sorry, this is unrelated. I should not have attached a new comment. I don't think I can delete it. If an admin can, please do so.
AEA PK232 at client site also is giving problem in WL2K Mode. At least for us around LA3F-10.
I don't think it has anything to do with Peer 2 Peer mode.

It worked very well many versions ago., some 1.0. x.y version.
I think the issue is under investigation.
+1

It is in RMS Express, it changes TNC settings to something goofy.

We stopped using RMS EXpress in Washington County, WI ARES because it is not reliable.

 

I am using PK96/100.  Have 2 TNC's, both have done that after latest updates.

Worked flawless before that.  Please get on the development teams butt to get this fixed.  I get no response on the yahoo group reflector..........

Seems if you don't have a kantronics they don't care about it.

I have seen this type of error message also, with latest RMS Express.
TNC is KPC3+ & both times it occurred, I had to delete the message and re-create it.


I am getting the same error

*** Link Error - Received data stream not correct format...


Im using the internal TNC on a Kenwood TM-D710GA.

This happens at 1200 and 9600 baud, with a very good connect to
a local node.

If I connect with Telnet, I can download the message.

Kenwood has no notes about link errors on their site.

Is this a WinLink problem?


73

Michael Newman

KM6KAQ